link_1
link_2
link_3
link_4
link_5
link_6

 

 

ESI

801

The 801 Generator-Detector features double-chassis constructions, or guarding, to greatly reduce stray leakage paths to ground. Leakage from the high generator terminal and from the high detector terminals to ground has been virtually eliminated. Specifications: Generator: 6 ranges, continuously variable, 0 to 600 V; Power limited to 1 W; 1 to 100 kohms; Detector: calibrated ±3 µV to ±1000 VDC end scale in 18 zerocenter ranges, sensitivity (uncalibrated) can be increased to about 0.75 µV end scale; ±5% accuracy of end scale, ±0.1 µV; ±15 µV limits of zero control.

 

Click to view more ESI equipment

 

Test Equipment Connection
Your Premium Source For Quality Used Equipment
30 Skyline Drive, Lake Mary, FL 32746

Tel: (407) 804-1299 Fax: (407) 804-1277
Tel: (800) 615-8378 Fax (800) 819-TEST
E-mail: Sales@TestEquipmentConnection.com
Copyright ©1999-2002, Test Equipment Connection, All rights reserved